SETsafe | SETfuseSETsafe | SETfuse
Language
SETsafe | SETfuse
SETsafe | SETfuse
SETsafe | SETfuse
SETsafe | SETfuse
SETsafe | SETfuse
Home
idea Thermal CutOff (iTCO)
  • idea Thermal CutOff (iTCO)
  • Applications

111111111.png


Usage


1. When atmosphere pressure is from 80 kPa to 106 kPa, the related altitude shall be from 2000 meter to - 500 meter.

2. Operating voltage less than rated voltage of iTCO, operating current less than rated current of iTCO.

3. Do not touch the iTCO body or leads directly when power is on, to avoid burn or electric shock.

 

Electrical Connections


Mechanical Connection MC

1. The product surface must not be damaged.

2. If adding terminals to electrode leads, make sure the electrode without grease or other foreign matters, and use the same  cross-section connection terminal, otherwise the electrode may heat abnormally.

3.  If locking with screw, to prevent loosening, please add gasket and use proper screw when installing the product. Ensure that the screw tightening torque meets the requirements.


Soldering CC

1. Soldering should be carried out under the soldering conditions listed in table-1.

2. Feed heater and remote signal CC contain thermal element , improper soldering operation (too high soldering temperature  , too long soldering time, too short lead wire etc.) may cause CC to open in advance.

3. When soldering conditions are more severe than those listed in table-1 , a heat sink fixture should be used between solder point and iTCO body.

 

TABLE-1 Hand - Soldering Time (s)


 4.Attention -iTCO-2.jpg


Test Methods


 Cold Resistance Test

1. If product TCR is not less than 350 E (-6) / °C and the test ambient temperature  is during 15 °C to 35 °C, the measured resistance value shall be corrected as the relative resistance value under 25 °C according to TCR formula.

2. Resistance Measurement (4-wire).

 

Replacement

 

iTCO is the non-resettable product, for safety sake, please use the same type of iTCO for replacement.

 

Storage


Please store the iTCO without high temperature , high humidity or corrosive gas. To avoid influencing the solder-ability of  the leads and influencing contact resistance, please use them up within 1 year after receiving the goods.